Quick answer: AC Not Blowing Cold / Recharge on a 2009–2017 Chevrolet Traverse is rated Moderate and takes about 30-60 minutes. You'll need 2 tools for this job, and parts cost about $45. This guide walks you through the full job step by step, including the mistakes to avoid.
| Part Name |
Part Number |
Price |
Buy |
| Correct refrigerant DIY kit with gauge (R-134a or R-1234yf as labeled) |
— |
$45.00 |
|
| AC leak-detect dye (optional) Optional |
— |
$12.00 |
|
About prices: shown prices are typical retail averages and change frequently; cheaper alternatives may be available. Confirm the current price before buying.
💡 Pro tip: Order all parts at once to save on shipping
Step-by-Step Instructions
Follow these steps carefully
1
Confirm refrigerant type and symptoms
Read the A/C sticker on the hood underside or radiator support. With the engine idling and A/C on MAX, confirm warm vents, check the compressor clutch at the front of the engine for engagement, and check the cabin filter behind the glovebox. Wear safety glasses and gloves — liquid refrigerant causes frostbite on contact.
🔧 Mechanic's note — Tom Becker
Front-only versus rear A/C changes the charge amount, so I read the sticker before buying anything. A single-can kit sized for a front-only system will leave a rear-A/C Traverse undercharged and still blowing lukewarm.
2
Find the low-side service port
Engine off, follow the larger aluminum suction line from the compressor back toward the firewall. Never force the connection and never charge through the high side; pressure there can burst the can or cause serious injury.
3
Take a baseline reading
Start the 2009-2017 Chevrolet Traverse, set the A/C to MAX with recirculate on and the blower at full speed, and wait two to three minutes. Verify the compressor clutch is engaged — the clutch plate should be spinning with the pulley rather than sitting still. Attach the kit gauge to the low-side port and compare the reading to the kit chart for the current ambient temperature. As a generic reference for R-134a, expect roughly 35-45 psi on the low side at 75 degrees F, rising to about 50-60 psi at 90 degrees. If the gauge reads near zero while the A/C is running, the system is essentially empty — especially common on rear-A/C Traverses with long line runs — and needs a shop's evacuate, leak-test, and recharge service.
4
Add refrigerant cautiously
If the system still holds a partial charge and the kit permits topping off, add R-134a in 5–10-second bursts through the low side, can upright, shaking gently between bursts. Don't mix refrigerants; don't empty cans blindly. Rear-A/C systems hold a larger charge — add gradually, since overcharging raises high-side pressure and can damage the compressor.
5
Stop and verify cooling
Disconnect the coupler from the 2009-2017 Chevrolet Traverse low-side port and screw the cap back on finger-tight to keep the fitting clean and dry. With the engine idling and recirculate on, the center vent should now read roughly 35-50 degrees F on a thermometer; on rear-A/C models, check the rear vents too. Inspect the compressor, line fittings, and the condenser ahead of the radiator for fresh oily film — on the Traverse, also glance at the long rear lines running under the body, a known leak spot. If the cold air disappears within days, the clutch never engages, or your baseline reading was near zero, take it to a shop for a UV dye or electronic leak test instead of recharging again — knowingly topping off a leaking system vents refrigerant, which is illegal.
🔧 Mechanic's note — Ray Delgado
Those long rear lines under the body are the Traverse's signature leak spot — they run the length of the truck and corrode where road grime packs in. I check them before I check anything under the hood when the rear vents go warm first.
All Done!
Test your repair before closing everything up. If something doesn't work right, double-check your steps.
⚠️ Common Mistakes to Avoid
- • Using the wrong refrigerant (R-134a vs R-1234yf)
- • Overcharging by watching a gauge without following the kit chart and vent temperature
- • Recharging an empty or badly leaking system
- • Connecting to the high-side port
- • Continuing to recharge when the system loses cooling again within days