2015–2020 Ford F-150

2015-2020 Ford F-150 - AC Not Blowing Cold / Recharge

By Ray Delgado ✓ Certified Mechanic · Published Sep 21, 2026 · Updated Oct 22, 2026

🔧🔧 Moderate 30-60 minutes $45 DIY

Save $305 by doing it yourself! Shop cost: $350

Quick answer: AC Not Blowing Cold / Recharge on a 2015–2020 Ford F-150 is rated Moderate and takes about 30-60 minutes. You'll need 2 tools for this job, and parts cost about $45. This guide walks you through the full job step by step, including the mistakes to avoid.

Quick Video Tutorial

Parts You Need

Total Cost
$45.00
Part Name Part Number Price Buy
Correct refrigerant DIY kit with gauge (R-134a or R-1234yf as labeled) — $45.00
AC leak detect dye (optional) Optional — $12.00

About prices: shown prices are typical retail averages and change frequently; cheaper alternatives may be available. Confirm the current price before buying.

💡 Pro tip: Order all parts at once to save on shipping

Step-by-Step Instructions

Follow these steps carefully

1

Confirm refrigerant type and symptoms

Read the under-hood A/C label (SAE J639) — it names the refrigerant and charge weight. Split range: 2015-2017 F-150s use R-134a; 2018-2020 use R-1234yf. Some third-party charts list the 2018 as R-134a, so treat the under-hood label as the authority, not this guide. Confirm warm vents on MAX A/C with recirc, and check the cabin filter behind the glove box: weak airflow mimics low charge.

🔧 Mechanic's note — Tom Becker

I don't trust any chart for the 2018 F-150 after seeing one list it as R-134a. The under-hood label settles it in ten seconds — that's the only source that matters on this year.

2

Prep and find the low-side port

Engine OFF. The low-side port sits on the larger suction line from the firewall evaporator to the compressor — follow it to the cap marked 'L'. The DIY hose clicks only onto that coupler; if it won't click, stop (wrong port or refrigerant family). Never force it or use adapters, and never touch the high-side 'H' cap.

3

Baseline pressure with A/C on

Start the engine: MAX A/C, coldest setting, recirc ON, blower on high. After 2-3 minutes, connect the gauge to the low-side port and compare against your kit's ambient-temperature chart. Near zero? Stop — an empty system needs professional evacuation, leak repair, and recharge by weight; a top-off won't fix it and liquid slugging can destroy the compressor.

4

Add refrigerant in short bursts

With the system running, add refrigerant in 5-10 second bursts with the can upright — vapor only, never inverted; liquid reaching the compressor can destroy it. Pause and re-check the gauge and vent temperature between bursts, aiming for the middle of the chart: overcharging raises head pressure and hurts cooling. On the R-1234yf side of the split, note it is mildly flammable (ASHRAE A2L) — no flames, ventilate. Never vent refrigerant to the atmosphere. Skip stop-leak cans: sealants clog the expansion valve or orifice tube.

🔧 Mechanic's note — Tom Becker

I add refrigerant in short 5-10 second bursts with the can upright — vapor only. Liquid reaching the compressor can destroy it, and with R-1234yf I treat the charge like fuel vapor: no smoking, good ventilation.

5

Stop criteria and wrap-up

Stop when low-side pressure matches the ambient chart and center vents blow cold (high-30s to mid-40s F on MAX). Disconnect the hose and firmly reinstall the 'L' cap — it's the primary seal — then recheck cooling after a short drive. Cooling fades within days? You have a leak: get a UV-dye inspection or shop leak-down test, not another can. Repeated top-offs without a repair waste money and risk the compressor.

All Done!

Test your repair before closing everything up. If something doesn't work right, double-check your steps.

⚠️ Common Mistakes to Avoid

  • • Using the wrong refrigerant (R-134a vs R-1234yf)
  • • Overcharging by watching can weight instead of gauge + vent temp
  • • Recharging an empty or badly leaking system
  • • Connecting to the high-side port